Integrated circuits, resistors, capacitors





Need Help Identifying a Relay – SDS DR5V

Hello,

     We are trying to identify an electromechanical relay on a PC board we
bought from OR Industrial Computers in Germany.  The markings on the case are:
SDS DR5V.  (The SDS looks like a logo). According to OR, it is rated to 160
volts AC and 3 amperes.  We would very much like to get a data sheet from the
original company.  The U.S. sales rep. said the relays may be from
Switzerland!  Any ideas?  

Thank you,

Glenn Lindamood
NASA-Lewis Reseach Center
GLindam…@lerc.nasa.gov

posted by admin in Uncategorized and have Comments (3)






3 Responses to “Need Help Identifying a Relay – SDS DR5V”

  1. admin says:

    In article <4qpmmk$…@sulawesi.lerc.nasa.gov>,

    Glenn Lindamood <GLindam…@LERC.NASA.GOV> wrote:
    >Hello,

    >     We are trying to identify an electromechanical relay on a PC board we
    >bought from OR Industrial Computers in Germany.  The markings on the case are:
    >SDS DR5V.  (The SDS looks like a logo). According to OR, it is rated to 160
    >volts AC and 3 amperes.  We would very much like to get a data sheet from the
    >original company.  The U.S. sales rep. said the relays may be from
    >Switzerland!  Any ideas?  

    Germany, more likely, but they are all over the place. Anyway, SDS was
    absorbed by Matsushita Automation Controls, some while back. Their
    catalog lists the relay with the following specs:

    Coil voltage:           5V (<4.0V pick-up, >0.3V drop-out)
    Coil resistance:        320 Ohms +/- 10%
    Contact arrangement:    1 Form C  ( = SPDT )
    Contact ratings:        33VA, 20W
    Max. contact voltage:   110V AC, 30V DC
    Max. contact current:   0.3A AC, 1A DC (Looks like that should be the inverse)

    There’s a lot more than that, but if this isn’t enough, you’d surely be
    better served by calling them. Their European head office is:

    EURO-Matsushita Electric Works AG
    Rudolf Dieselring 2
    D-W-8150 Holzkirchen
    Germany
    FAX +(8024) 648 111

    I don’t have addresses of US representatives, sorry. If all else
    fails ask again.

    Regards,
    Jeroen Belleman
    Jeroen.Belle…@cern.ch

  2. admin says:

    That was most helpful!  The catalog is on it’s way.  Sometimes usenet does
    ‘come thru’.

    thanks,

    mark

    ps  For anybody else the number has been changed to 410 453-6600.  m


    mark stephens                mark.steph…@gsfc.nasa.gov
    code 521.2                   (301) 286-4269
    NASA/GSFC
    Greenbelt, MD 20771

  3. admin says:

    - Hide quoted text — Show quoted text -

    mark stephens wrote:

    > I’ve tried calling NEC literature and they said they no longer carry
    > databooks for these parts or that the parts were coming from Japan.  The
    > NEC person gave me numbers for B&D and MCM, neither carry a databook.

    > I’m looking for a datasheet on a NEC 2501, 2, 3, or 4 opto-isolator.

    > thanks,

    > mark

    > —
    > mark stephens                mark.steph…@gsfc.nasa.gov
    > code 521.2                   (301) 286-4269
    > NASA/GSFC
    > Greenbelt, MD 20771

    I can send a photocopy of "NEC PS2501 -1, -2, -3 ,-4 PHOTO COUPLERS" datasheet
    by mail to you. Let me know if you’re still interested! and also your address.

    A Reader from Toronto, ON …..







Place your comment